WEKO3
アイテム
APPLICATION OF ISO-BASED POSTURE MEASUREMENT SYSTEM "rysis" TO CLINICAL GAIT ASSESSMENT : Reliability of body segment angles in the absence of external markers
https://kawasakigakuen.repo.nii.ac.jp/records/124
https://kawasakigakuen.repo.nii.ac.jp/records/12483fe5129-06d3-4234-bfdf-24df4c81a963
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2020-06-12 | |||||||||||
タイトル | ||||||||||||
タイトル | APPLICATION OF ISO-BASED POSTURE MEASUREMENT SYSTEM "rysis" TO CLINICAL GAIT ASSESSMENT : Reliability of body segment angles in the absence of external markers | |||||||||||
言語 | en | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Observation | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Gait assessments | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Marker | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Body segment line | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Reliability | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | ISO 16840-1 | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | rysis | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||
資源タイプ | departmental bulletin paper | |||||||||||
内容種別 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | Original Article | |||||||||||
著者 |
Toru FURUI
× Toru FURUI
× takahiro NISHINOHARA
× Fumitaka FUJINO
|
|||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | Whilst instrumented gait assessment is the gold standard for gait analysis, visual gait observation is commonly used to determine gait disorders and to evaluate treatment in clinical practice. Because the instrumented gait assessment is laboratory-based, expensive, and time and energy consuming, it is not commonly available in the context of routine clinical practice. The purpose of this study was to examine the reliability of therapist observations in the gait assessment process using the quantitative measurement tool “rysis” which is based on ISO 16840-1 standard. Inter-rater reliabilities of 12 physical therapists were assessed and compared under two conditions: with (ICC=0.970) and without (ICC=0.902) externally placed visible body landmark markers. In addition we explored potential power of the application of “rysis” in clinical gait analysis performed by physical therapists. | |||||||||||
言語 | en | |||||||||||
書誌情報 |
ja : 大阪河﨑リハビリテーション大学紀要 en : Journal of Osaka Kawasaki Rehabilitation University 巻 8, 号 1, p. 17-27, 発行日 2013-10 |
|||||||||||
出版者 | ||||||||||||
出版者 | 大阪河﨑リハビリテーション大学 | |||||||||||
言語 | ja | |||||||||||
ISSN | ||||||||||||
収録物識別子タイプ | PISSN | |||||||||||
収録物識別子 | 1881-509X | |||||||||||
論文ID(NAID) | ||||||||||||
識別子タイプ | NAID | |||||||||||
関連識別子 | 40019917760 | |||||||||||
書誌レコードID | ||||||||||||
収録物識別子タイプ | NCID | |||||||||||
収録物識別子 | AA12235266 |